1. replacement parts
2. Engineer telecommunication
3. manual instructions and
4.Favorable re-purchase price
Driver type | Profile and mounting size(mm) | ||||||||||||||
W | H | D | W1 | W2 | H1 | Mounting aperture | Reactor | ||||||||
SCK500-4T1.5GB | 81 | 237 | 173 | 67.5 | 57 | 224.5 | 4.5 | ||||||||
SCK500-4T2.2GB | |||||||||||||||
SCK500-4T3.7GB | |||||||||||||||
SCK500-4T5.5GB | |||||||||||||||
SCK500-4T7.5GB | 95 | 297 | 222 | 73.5 | 73.5 | 287.5 | 6 | ||||||||
SCK500-4T11GB | |||||||||||||||
SCK500-4T15GB | |||||||||||||||
SCK500-4T18.5GB | 185 | 440 | 249 | 140 | 140 | 427.5 | 7 | Mathching | |||||||
SCK500-4T22GB | |||||||||||||||
SCK500-4T30GB | |||||||||||||||
SCK500-4T37G | 239 | 604.5 | 269.5 | 180 | 148.5 | 580 | 9.5 | ||||||||
SCK500-4T45G | |||||||||||||||
SCK500-4T55G | 265 | 690 | 323 | 200 | 148.5 | 250 | 9.5 | ||||||||
SCK500-4T75G | |||||||||||||||
SCK500-4T90G | 295 | 833.5 | 338.5 | 200 | 200 | 810 | 12 | ||||||||
SCK500-4T110G | |||||||||||||||
SCK500-4T132G | |||||||||||||||
SCK500-4T160G | 350 | 1070 | 407 | 265 | 265 | 1046.5 | 14 | ||||||||
SCK500-4T185G | |||||||||||||||
SCK500-4T200G | |||||||||||||||
SCK500-4T220G | 339 | 1104.5 | 498 | 265 | 175 | 1081.5 | 14 | ||||||||
SCK500-4T250G | |||||||||||||||
SCK500-4T280G | |||||||||||||||
SCK500-4T315G | 660 | 1339.5 | 392 | 600 | 550 | 1312 | 14 | Standard bulit-in | |||||||
SCK500-4T355G | |||||||||||||||
SCK500-4T400G | |||||||||||||||
SCK500-4T450G | |||||||||||||||
SCK500-4T500G | 850 | 1600 | 600 | -- | -- | -- | 16 | ||||||||
SCK500-4T560G | |||||||||||||||
SCK500-4T630G | |||||||||||||||
SCK500-4T710G |
Enter | Rated voltage frequency | Three phase AC380V;50/60Hz Single phase AC220V;50/60Hz | |||
Voltage allowable range | Three phase AC360V ~450V Single phase AC190V ~250V | ||||
Output | Voltage | 0~460V 0 ~260V | |||
Rrequency | Low frequency mode 0~ 300Hz High frequency mode 0 ~3000Hz | ||||
Overload capacity | Model G: 110% long-term 150% 1 minute 200% 4 seconds P type machine: 105% long-term 120% 1 minute 150% 1 second | ||||
Way to control | V/F control, advanced V/F control, V/F separation control, current vector control without PG | ||||
Control characteristics | Frequency setting resolution | Analog input | Digital setting | ||
Digital setting | 0.01Hz | ||||
Frequency accuracy | Analog input | Within 0.2% of the maximum output frequency | |||
Digital input | Set within 0.01% of output frequency | ||||
V/F control | V/F curve (voltage frequency characteristic) | The reference frequency is arbitrarily set at 0.5 ~3000Hz, and the multi-point V/F curve is arbitrarily set. You can also choose constant torque, reduced torque 1, reduced torque 2, square torque and other fixed curves | |||
Torque boost | Manual setting: 0.0 ~30.0% of rated output Automatic boost: automatically determine the boost torque according to the output current combined with the motor parameters | ||||
Automatic current limit and pressure limit | Whether in the process of acceleration, deceleration or stable operation, it can automatically detect the stator current and voltage of the motor, and suppress it within the allowable range according to a unique algorithm, minimizing the possibility of system fault tripping | ||||
Control characteristics | Sensorless vector control | Voltage frequency characteristics | Automatically adjust the output voltage-frequency ratio according to motor parameters and unique algorithms Torque characteristics Starting torqu | ||
Torque characteristics | Starting torque: 150% rated torque at 3.0Hz(VF control) 150% rated torque at 1.0Hz(advanced VF control ) 150% rated torque at 0.5Hz (no PG current vector control)Steady-state accuracy of operatin g speed: ≤±0.2% of rated synchronous speed Speed fluctuation: ≤±0.5% of rated synchrono us speed Torque response: ≤20ms (No PG current vector control) | ||||
Typical function | PID control RS485 communication | Built-in PID controller (frequency can be preset). Standard configuration RS485 communication function, multiple communication protocols are optional, with linkage synchronization control function | |||
Frequency setting | Analog input | DC voltage 0 ~10V, DC current 0 ~20mA (upper and lower limit optional) | |||
Digital input | Operation panel setting, RS485 interface setting, UP/DW terminal control, and multiple combination settings with analog input | ||||
output signal | Digital output | 2 channels Y terminal open collector output and 2 channels programmable relay output (TA, TB, TC), up to 61 meaning options+ | |||
Analog output | 2 analog signal output, the output range can be flexibly set between 0 ~20mA or 0 ~10V, which can realize the output of physical quantities such as set frequency and output frequency |
Counter | One internal counter to facilitate system integration | ||||||
Run function | Upper and lower limit frequency setting, frequency jump operation, reverse operation limit, slip frequency compensation, RS485 communication, frequency increase and decrease control, fault self-recovery operation, etc. | ||||||
Display | Operation panel display | Operating status | Output frequency, output current, output voltage, motor speed, set frequency, module temperature, PID setting, feedback quantity, analog input and output, etc. | ||||
Alarm conten | The last six fault records, the output frequency, set frequency, output current, output voltage, DC voltage, module temperature and other 6 operating parameter records at the time of the last fault trip | ||||||
Protective function | Overcurrent, overvoltage, undervoltage, module failure, electronic thermal relay, overheating, short circuit, input and output phase loss, abnormal motor parameter tuning, internal memory failure, etc. | ||||||
Surroundings | Ambient temperature | -10℃~+40℃(the ambient temperature is between 40℃~50℃, please use with derating) | |||||
Ambient humidity | 5% ~95%RH, no condensation | ||||||
Surroundings | Indoor (no direct sunlight, no corrosion, flammable gas, no oil mist, dust, etc.) | ||||||
Altitude | Derating for use above 1000 meters, derating 10% for every 1000 meters | ||||||
Structure | Protection level | IP20 | |||||
Cooling method | Air cooling, with fan control | ||||||
Installation method | Wall-mounted, cabinet |